Skip to content

Engineering data · Material

430 Stainless Steel Sensor Housings

By Yu Lianbo — Tooling Design Engineer

In one line

430 is ferritic and magnetic. Where a housing is part of a magnetic circuit - a shield, a flux path or a clamp - the grade is chosen for its magnetic response, not for corrosion resistance.

Published configurations in this grade

9 published configurations use SUS 430, across the denso-heat-shields, injector-egt series. Heights run 17.8-53.6 mm, outer diameters 7.90-19.60 mm, recorded wall thicknesses 0.50, 1.00 mm.

CodeSeriesHeightODIDWallMaterial
K001injector-egt43.2 mm11.3,14.9 mm10.3,14 mm0.5 mmsus 430
K005injector-egt17.8 mm12,10.9 mm11,7.9 mm0.5 mmsus 430
K005-3injector-egt17.8 mm12,10.9 mm11,7.9 mm0.5 mmsus 430
K006injector-egt21.6 mm13.75,8.8,11.7 mm11.75,7.1 mm1.0 mmsus 430
K006-2injector-egt18.8 mm13.3,8.8 mm11.75,7.1 mm1.0 mmsus 430
J024-3denso-heat-shields49 mm15.9,18.6,19.6 mm14.9,17.6,18.6 mm0.5 mmsus 430
J025-4denso-heat-shields53.6 mm15.9,18.6,19.6 mm14.9,17.6,18.6 mm0.5 mmsus 430
J004-1denso-heat-shields34.4 mm11.6,15 mm10.7,14 mm0.5 mmsus 430
J004-2denso-heat-shields44.5 mm7.9,11.3,15 mm6.9,10.3,14 mm0.5 mmsus 430

Where 430 belongs

Magnetic shields, flux-path components and heat shields where the part must be magnetic and cost matters. It sits below the 300 series on corrosion resistance and drawability, which is why it is used for shallower or less demanding draws.

What to expect when it is pressed

430 has lower formability and no nickel to keep the austenitic structure ductile; deep parts need a conservative draw schedule and clean tooling. Springback is noticeably different from the austenitic grades.

Checking the magnetic requirement

If the drawing specifies a magnetic response, state the requirement explicitly - grade alone is not a magnetic specification, and heat treatment can change it.

Grade, wall thickness and tolerance are confirmed against the customer drawing. Batch heat treatment, slow wire cutting, passivation, electropolishing, plating, phosphating and coating are placed with qualified external processors and disclosed on the inspection plan.

Frequently asked questions

How many SUS 430 configurations does Balford publish?

The published catalogue contains 9 SUS 430 configurations, each recorded with height, outer diameter, inner diameter and material per catalogue code.

What sizes are available for SUS 430 parts?

Recorded heights run 17.8-53.6 mm and outer diameters 7.9-19.6. Custom sizes are manufactured to the customer drawing rather than limited to the catalogue.

Which materials are used?

The published configurations use SUS 430. Material, temper and wall thickness are confirmed against the drawing before tooling.

What wall thickness is typical?

Recorded wall thicknesses in this family: 0.50, 1.00 mm.

How do I get a quotation?

Send a 2D drawing or 3D model with the material, annual volume and the tolerances that matter. A DFM review covering draw ratio, forming stages and thinning comes back before tooling, and the quotation separates tooling cost from piece price.

Written by the Balford engineering team, Zhuji, Zhejiang, China. Last updated 21 September 2026.